| Item No | ACM Series |
| Item Name | ACM Series, Antenna and Cable Monitors |
| Frequency Range | 136-225 MHz 225-520 MHz 470-960 MHz 960-2400 Mhz |
| Measurement Range | ACM: 2.5 W to 100 W ACM 500: 12.5 W to 500 W |
| Power Accuracy | 136-225 MHz, ± 10% 225-520 MHz, ± 8% 470-960 MHz, ± 5% 960-2400 MHz, ± 5% |
| Insertion Loss | 0.1 dB (136 - 960 MHz) 0.15 dB (960 - 2400 MHz) |
| VSWR | 1.07 (136 to 960 MHz) 1.1 (960 to 2400 MHz, N Connectors) 1.1 (960 to 2000 MHz, 7/16 Connectors) 1.2 (2000 to 2400 MHz, 7/16 Connectors) |
| Reflected Directivity | 30 dB (136 to 960 MHz) 26 dB (960 to 2400 MHz) |
| Alarm Characteristics-VSWR | Alarm Set Point: 1.3, 1.4, 1.5, 1.6, 1.7, 1.8, 1.9, 2.0, 2.1, 2.2, 2.3, 2.4, 2.5 to 1 Relay Contact Type: Dry, Form C, relay contacts, common, normally open, normally closed Contact Rating: 100 VDC @ 0.5A Visual Alarm: Red LED will illuminate to indicate alarm Stimulus: VSWR set point exceeded, response time proportional to overload Reset: Local Mechanical reset switch Remote input (Reset if VDC is 0 to +0.8 volts) Push to Talk: +5/+24 VDC to activate |
| Monitor Ports | Connectors: Female N, TNC or BNC Coupling: -63 dB approx., Subject to changes in full-scale power |
| Interface Port | Connector: Female DB-9, compatible with IBM PC AT serial port Protocol: Serial RS-232, 9600 baud, no parity, 8 data bits, 1 stop bit, no handshake |
| General | Thruline® sensor for direct insertion in 50-ohm line |
| RF Connectors | N or 7/16 DIN, see chart above |
| Maximum Line Section Power | Dependent on frequency and connector |
| Alarm--Power Connector | 15-pin Female “D” connector |
| Temperature | Operating: 0 to 50°C Storage: -20 to 80°C |
| Humidity | 0 to 95% (non-condensing) max. |
| Altitude | Up to 3000 meters above sea level |
| Passive Intermodulation Products | Less than -130 dBc |
| Power Requirements | +11 to +26 VDC or ±36 to ±72 VDC |
| Dimensions | 4.75” (121 mm) wide (7.55” (192.mm) with connectors) 4.2” (107mm) high, 1.06“ (27mm) deep |
| Weight | Less than 2 lbs. (0.9 kg) |
| EMC | European Standard EN 61326-1:1997 + Addendums A1: 1998 and A2:2001 - Electrical equip. for measurement |
| Safety | European Standard EN 61010-1:2001 - Safety Requirements - Electrical equip. for measurement, control and laboratory use - ECM Requirements. |